Earthwise Design Solutions

PORTFOLIO OF EXCELLENCE

Engineered Benchmarks in
High-Performance Architecture

From 500-Acre sustainable townships and district cooling master plans to Net-Zero corporate headquarters and ISO Class 6 semiconductor cleanrooms—explore our team's landmark project experience.

500+ Acre Master Planning Scale
3,500 TR District Cooling Capacity
Net-Zero Energy Validated Facilities
35%+ Radiant Energy Savings
Dhun Life Integrated Township, Jaipur
500 Acre Township
Jaipur, Rajasthan

Dhun Life Integrated Township

Master plan MEP design featuring 380M-liter lake networks, peripheral HT substation routing, centralized chilled water loop, on-site solar PV, and underground utility service corridors.

Centralized Chilled Water Solar & Biogas Water Balancing
Nalanda University Campus District Cooling
~3,500 TR District Cooling
Rajgir, Bihar

Nalanda University Campus

Massive multi-plantroom district chilled water network serving Academic Spine (1106 TR), Student Hostels (670 TR), Faculty Housing (1110 TR), and Outreach with 5-zone residential optimization.

District Chilled Water 4 Central Plantrooms 5-Zone Optimization
Jaquar Global Headquarters Net-Zero
First Net-Zero Office in North India
Gurugram, Haryana • 1,37,200 Sqft

Jaquar Global Headquarters

Net-Zero landmark achieving 35% less energy using a 450 TR radiant cooling system, automated plantroom staging, sensor-integrated low side, and 1 MW rooftop solar PV array.

Radiant Cooling (450 TR) 1 MW Solar PV Net-Zero Validated
Dixon Technology Semiconductor Manufacturing
Cleanroom ISO Class 6
Noida, Uttar Pradesh • 4,00,000 Sqft

Dixon Technology Manufacturing

High-precision HVAC and electrical infrastructure for semiconductor assembly featuring ISO Class 6 cleanroom conditions, positive pressure control, and specialized process exhaust systems.

Cleanroom Applications Central Chilled Water Industrial MEP
W Hotel Hitech City, Hyderabad
170 Keys Luxury Hospitality
Hitech City, Hyderabad • 2,70,000 Sqft

W Hotel, Hitech City

Complete centralized chilled water system with whisper-quiet low-noise acoustics, high guestroom ventilation IAQ standards, domestic hot water heat recovery, and guest automation integration.

Central Chilled Water Acoustic Attenuation Energy Recovery
Indian Institute of Art & Design IIAD Gurugram
EPI 48 kWh/m²/yr (53% Savings)
Gurugram, Haryana • 4,00,000 Sqft

Indian Institute of Art & Design (IIAD)

Net-Zero targeted campus with centralized radiant cooling, SuperECBC envelope tuning (EPI lowered from 102 to 48), daylight harvesting, EV charging stations, and smart IBMS building controls.

Radiant Cooling SuperECBC 2017 Solar PV Offset
Jaquar Lighting Office & Factory Bhiwadi
6,70,000 Sqft • 600 TR • 1 MW PV
Bhiwadi, Rajasthan

Jaquar Lighting Office & Factory

Primary variable chilled water system, cleanroom 10k/100k application, EC-motor AHUs, PNG gas genset waste heat recovery, and an on-site cafeteria biogas plant for zero-waste production.

Primary Variable Chiller 1 MW Solar PV Cleanroom Class 10k
Devanya Mountain Development Bhimtal
90 Acre Eco-Luxury Master Plan
Bhimtal, Uttarakhand • RAAS Brand

Devanya Mountain Development

Luxury hospitality and 60 private villas planned with underfloor radiant space heating, centralized heat pump water heating, natural gravity rainwater distribution, and zero-pumping water networks.

Radiant Space Heating Gravity Water Loop EV Ready Campus
Rajasthan Central University CURAJ Geothermal Campus
Geothermal Ground Loop
Bandarsindri, Rajasthan

Rajasthan Central University (CURAJ)

Pioneering campus using geothermal multi-borewell ground heat exchange coupled with an Earth Air Tunnel (EAT) passive cooling network, achieving ultra-low EPI in hot-arid climate.

Geothermal Borewells Earth Air Tunnel (EAT) Passive Cooling
Apple Warehouse & Corporate Office Mumbai
German Standard Logistics
Mumbai, Maharashtra • 80,000 Sqft

Apple Warehouse & Corporate Office

Fully air-conditioned warehouse designed to German engineering standards with dual-mode operational efficiency, free-cooling economizers, and strict ambient temperature & humidity controls.

Dual-Mode Free Cooling German Standards Logistics MEP
Mehra High-End Luxury Residence New Delhi
1,25,000 Sqft Luxury Estate
New Delhi NCR

Mehra High-End Luxury Residence

Underfloor radiant cooling embedded throughout 1,25,000 sqft estate, sun-tracking motorized curtains, personalized climate zoning, pulse fencing perimeter security, and full digital lighting automation.

Underfloor Radiant Sun-Tracking Curtains BMS Home Automation
Jaquar Flagship Experience Stores Pan-India
Pan-India Experience Centers
Indore, Jaipur, Guwahati, Raipur, Siliguri, Vizag, Rajkot

Jaquar Flagship Experience Stores

Series of high-traffic retail flagships (up to 50,000 sqft) featuring occupant-sensor triggered instant cooling, radiant cooling (Indore), high-COP VRF systems, and optimized low-E facade retrofits.

Occupancy VRF Radiant (Indore 120 TR) EPI < 60 kWh/m²/yr
BROADER TRACK RECORD

Major Plumbing, Fire & Hospitality Projects

In addition to standalone consulting, our senior team and associates have spearheaded MEP, fire fighting, and public health engineering across renowned hospitality, retail, and corporate hubs:

Marriott Hotel, Hyderabad (2,75,000 Sqft)
ITC Narmada, Ahmedabad (3,00,000 Sqft)
Indian Embassy at Kathmandu, Nepal
Indian Consulate, Jeddah, KSA
IREO The Grand Arch & Raheja Mall, Gurgaon
Quark City Office, Mall & Hotel, Mohali
United Spirits (USL) Factories at Alwar & Baddi
Bharti Walmart Cash & Carry Outlets

Have an Ambitious Project in Mind?

Let us collaborate with your architectural and development team to engineer an ultra-efficient, cost-optimized, and sustainable mechanical and electrical design.

Scroll to Top